Home / Air Blow Heater / products / Air Blow Heater Controller / Overview of the high-performance air blow heater controller AHC2 series

Overview of the high-performance air blow heater controller AHC2 series

Overview of the high-performance air blow heater controller AHC2 series

【 Feature 】

AHC2 is a heater controller that combines options with basic functions and is customized for use.
By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
At a flow rate management by a flow control valve with a float-type flow meter, a flow control valve with a digital flow meter, or mass flow controller, to ensure the reproducibility of the amount of heat supplied.
Thermocontroller on-board of the option selected, there is a thermocouple specification or a radiation thermometer specification.
In option selected, user can control of ON-OFF and the voltage is possible with the outside signal.
The IOT-function of the option selected, user can confirm data such as, the set temperature, heating temperature, operation time, operation number of times, heater exchange number of times.
Using a duplication sensor of the optional selected, a over temperature alarm management is possible.
Using a one-shot timer of the optional selected, an precision heating examination is possible.

【 Model configuration list 】

Overview of the high-performance air blow heater controller AHC2 series

【 Basic Specifications 】

Overview of the high-performance air blow heater controller AHC2 series

Overview of the high-performance air blow heater controller AHC2 series

1.Thermocontroller & digital flow meter  AHC2-TCDFM

By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
At a flow rate management by the flow control valve with a digital flow meter, to ensure the reproducibility of the amount of heat supplied.
The built-in no-gas heating prevention function and prevents heat damage to the heater.

Overview of the high-performance air blow heater controller AHC2 series

Overview of the high-performance air blow heater controller AHC2 series

2.Thermocontroller &float type flow meter AHC2-TCFM

By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
At a flow rate management by the flow control valve with a float-type flow meter, to ensure the reproducibility of the amount of heat supplied.

Overview of the high-performance air blow heater controller AHC2 series

Overview of the high-performance air blow heater controller AHC2 series

3.Thermocontroller & float type flow meter with remote control AHC2-TCFMRC

By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
At a flow rate management by the flow control valve with a float-type flow meter, to ensure the reproducibility of the amount of heat supplied.
AHC2-TCFMRC come with a heater by a remote control function in ON-OFF from the outside.
This controller corresponds to the IOT era in the rich options.

Overview of the high-performance air blow heater controller AHC2 series

Overview of the high-performance air blow heater controller AHC2 series

4.Thermocontroller & float type flow meter with over-heat control AHC2-TCFMSV

By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
At a flow rate management by the flow control valve with a float-type flow meter, to ensure the reproducibility of the amount of heat supplied.
To prevent in advance the heater disconnection and accidents caused by excessive temperature rise by the excessive rise in temperature monitoring function.

Overview of the high-performance air blow heater controller AHC2 series

Overview of the high-performance air blow heater controller AHC2 series

5.Thermocontroller & mass flow controller AHC2-TCFC

By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
By the mass flow controller, it enables high-precision air flow control.
The temperature controller and mass flow controller, to ensure the reproducibility of the amount of heat supplied.

Overview of the high-performance air blow heater controller AHC2 series

Overview of the high-performance air blow heater controller AHC2 series

6.Thermocontroller & massflowcontroller with remote control AHC2-TCFCRC

By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
By the mass flow controller, it enables high-precision air flow control.
The temperature controller and mass flow controller, to ensure the reproducibility of the amount of heat supplied.
AHC2-TCFCRC come with a heater by a remote control function in ON-OFF from the outside.
This controller corresponds to the IOT era in the rich options.

Overview of the high-performance air blow heater controller AHC2 series

Overview of the high-performance air blow heater controller AHC2 series

7.Thermocontroller & mass flow controller with over-heat control AHC2-TCFCSV

By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
By the mass flow controller, it enables high-precision air flow control.
The temperature controller and mass flow controller, to ensure the reproducibility of the amount of heat supplied.
To prevent in advance the heater disconnection and accidents caused by excessive temperature rise by the excessive rise in temperature monitoring function.

Overview of the high-performance air blow heater controller AHC2 series

Overview of the high-performance air blow heater controller AHC2 series

8.Thermocontroller & massflowcontroller with remote control & over-heat control AHC2-TCFCRCSV

By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
By the mass flow controller, it enables high-precision air flow control.
The temperature controller and mass flow controller, to ensure the reproducibility of the amount of heat supplied.
AHC2-TCFCSVRC come with a heater by a remote control function in ON-OFF from the outside.
This controller corresponds to the IOT era in the rich options.
To prevent in advance the heater disconnection and accidents caused by excessive temperature rise by the excessive rise in temperature monitoring function.

Overview of the high-performance air blow heater controller AHC2 series

Overview of the high-performance air blow heater controller AHC2 series

2.Power Cable for Heater Controller

Manufacture the specification of the power cable.

Overview of the high-performance air blow heater controller AHC2 series

Overview of the high-performance air blow heater controller AHC2 series

Overview of the high-performance air blow heater controller AHC2 series

When the plug or the connector which the upper figure does not have are necessary, we will manufacture as much as possible.

<< Quotation model specification method >>
(Heater controller model) – (Plug shape) – (Cable length)

<< Quotation example >>
HCA-AC100/220V-15A-TypeA-5m

 