Home / Air Blow Heater / products / Air Blow Heater Controller / Overview of the high-performance air blow heater controller AHC2 series

Overview of the high-performance air blow heater controller AHC2 series

Thermocontroller &float type flow meter AHC2-TCFM

Overview of the high-performance air blow heater controller AHC2 series

By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
At a flow rate management by the flow control valve with a float-type flow meter, to ensure the reproducibility of the amount of heat supplied.

Thermocontroller &float type flow meter AHC2-TCFM

Thermocontroller &float type flow meter AHC2-TCFM

Thermocontroller & float type flow meter with remote control AHC2-TCFMRC

By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
At a flow rate management by the flow control valve with a float-type flow meter, to ensure the reproducibility of the amount of heat supplied.
AHC2-TCFMRC come with a heater by a remote control function in ON-OFF from the outside.
This controller corresponds to the IOT era in the rich options.

Thermocontroller & float type flow meter with remote control AHC2-TCFMRC

Thermocontroller & float type flow meter with remote control AHC2-TCFMRC

Thermocontroller & float type flow meter with over-heat control AHC2-TCFMSV

By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
At a flow rate management by the flow control valve with a float-type flow meter, to ensure the reproducibility of the amount of heat supplied.
To prevent in advance the heater disconnection and accidents caused by excessive temperature rise by the excessive rise in temperature monitoring function.

Thermocontroller & float type flow meter with over-heat control AHC2-TCFMSV

Thermocontroller & float type flow meter with over-heat control AHC2-TCFMSV

Thermocontroller & massflowcontroller、AHC2-TCFC

By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
By the mass flow controller, it enables high-precision air flow control.
The temperature controller and mass flow controller, to ensure the reproducibility of the amount of heat supplied.

Thermocontroller & massflowcontroller、AHC2-TCFC

Thermocontroller & massflowcontroller、AHC2-TCFC

Thermocontroller & massflowcontroller with remote control AHC2-TCFCRC

By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
By the mass flow controller, it enables high-precision air flow control.
The temperature controller and mass flow controller, to ensure the reproducibility of the amount of heat supplied.
AHC2-TCFCRC come with a heater by a remote control function in ON-OFF from the outside.
This controller corresponds to the IOT era in the rich options.

Thermocontroller & massflowcontroller with remote control AHC2-TCFCRC

Thermocontroller & massflowcontroller with remote control AHC2-TCFCRC

Thermocontroller & massflowcontroller with over-heat control AHC2-TCFCSV

By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
By the mass flow controller, it enables high-precision air flow control.
The temperature controller and mass flow controller, to ensure the reproducibility of the amount of heat supplied.
To prevent in advance the heater disconnection and accidents caused by excessive temperature rise by the excessive rise in temperature monitoring function.

Thermocontroller & massflowcontroller with over-heat control AHC2-TCFCSV

Thermocontroller & massflowcontroller with over-heat control AHC2-TCFCSV

Thermocontroller & massflowcontroller with remote control & over-heat control AHC2-TCFCRCSV

By overheating zero setting of the thermocontroller, it makes the stable hot-air heating.
By the mass flow controller, it enables high-precision air flow control.
The temperature controller and mass flow controller, to ensure the reproducibility of the amount of heat supplied.
AHC2-TCFCSVRC come with a heater by a remote control function in ON-OFF from the outside.
This controller corresponds to the IOT era in the rich options.
To prevent in advance the heater disconnection and accidents caused by excessive temperature rise by the excessive rise in temperature monitoring function.

Thermocontroller & massflowcontroller with remote control & over-heat control AHC2-TCFCRCSV

Thermocontroller & massflowcontroller with remote control & over-heat control AHC2-TCFCRCSV

Overview of the high-performance air blow heater controller AHC2 series

【Options】

Abbreviation Contents
RC1 Remote Control switch mounted surface, heating start and stop from the outside.
SV Supervisor function for Over-heat protect or Target-heating
HL High-Low Control for rapid-heating or preheating
TMR1 The setting timer one-shot heating and mounting surface.
AirV Air opening and closing valve
OFDT Air closing valve, heating stop after the cooling timer 5 minutes
RSP Specify the 4-20mA a setting from the outside.
MON The current value to the external output in 4-20mA.
RS485 RS-485 Communication
IOT IOT function
BO Heater burnout ( Disconnection ) Alarm
AP Air pressure shortage Alarm
FPR Front Protection Rail
RPR Rear Protection Rail
TP Replaced by thermocontroller of the pyrometer input specification.
PM Pyrometer mounted surface.
Pyrometer Pyrometer to choice of applications, and then fitted adjusted to the heater controller.
Power Cable Manufacture the specification of the power cable.

[Note] When the to add a function, there is the external dimensions changes.

【 Options Front Protection Rail 】【 Options Rear Protection Rail 】

PDF Catalog Download