2-6.High-speed flow control with solenoid valve

High-speed flow control with solenoid valve

When air is controlled by an electromagnetic valve for high-speed flow control.

As shown in the above figure, please install a shocking absorption valve in an electromagnetic valve and parallel, and even when an electromagnetic valve is OFF, secure the minimum flow style.

Please install the solenoid valve upstream of a flow control valve.

If this becomes reverse, at the moment of turning on the solenoid valve, high pressure will be added to the Air Blow Heater  and will carry out a bad influence to the heater.

In case of the composition of the above figure, during OFF of the solenoid  valve,  hot air temperature is the same, and only a flow falls and it will be in a standby state.

Then the solenoid  valve is set to ON, the hot air of a quick predetermined temperature will be obtained.

If water and oil are contained in air, a bad influence will be carried out to the flow instrument and the heater.

Please be sure to use the air which removed oil and moisture.

【 Note 】

Water and oil are include in the air, a bad affect will be carried out to the flow-meter and the Air Blow Heater.

Please be sure to use the air which removed oil and moisture.