Home / Best Applications List

Best Applications List

No.60 Chemical liquid heater

[ Problem Point ] There was no good heater that could heat the chemical liquid at high speed. [ ⇒Kaizen Point ] Three halogen line heaters were combined to create a triangular space, and a quartz tube was passed through. ...

Read More »

Melting silicon wafer

This video is a demonstration of Melting silicon wafer with the Halogen Point Heater. Please check the following site for more information.

Read More »

Aluminum pipe brazing

This video is a demonstration of Aluminum pipe brazing with the Halogen Point Heater. Please check the following site for more information.

Read More »

No.29 Low temperature aging of electronic parts

《Problem Point 》 There was no good equipment for in-line low temperature electronic components. 《⇒Kaizen Point 》 An Air Blow Cooler was used. Furthermore, since the set temperature can be maintained with the cool air cooler controller, the product quality ...

Read More »

No.26 Cold resistance test of color filter

《Problem Point 》 There was no good equipment to cool the color filter. 《⇒Kaizen Point 》 An Air Blow Cooler was used. Since the set temperature can be maintained with the Air Cooler Controller, the inspection accuracy has increased.

Read More »

No.24 High temperature sensor cooling

《Problem Point 》 With air purging alone, the temperature of the sensor exceeded the specification range, which was a problem. 《⇒Kaizen Point 》 An Air Blow Cooler was used. Temperature drift was suppressed and measurement accuracy was improved.

Read More »

No.19 Cooling film cutting blade

《Problem Point 》 The resin was fused to the cutting blade due to frictional heat, which was a problem. 《⇒Kaizen Point 》 An Air Blow Cooler was used. The MTBF was improved because the resin did not adhere.

Read More »

No.18 Cooling during film fusion sealing

《Problem Point 》 When the film was fused, it was sometimes peeled off due to residual heat. 《⇒Kaizen Point 》 An Air Blow Cooler was used. After thermocompression bonding, it was cooled by removing heat with a Air Blow Cooler. ...

Read More »

No.16 Electronic component cooling test

《Problem Point 》 There was no good equipment to pinpoint the electronic component to a low temperature. 《⇒Kaizen Point 》 An Air Blow Cooler was used. Pinpoint cooling is possible with the needle nozzle. Since the set temperature can be ...

Read More »

No.15 Printed circuit board cooling

《Problem Point 》 There was no good equipment to cool the printed circuit board after soldering. 《⇒Kaizen Point 》 An Air Blow Cooler was used. Since the set temperature can be maintained with the cool air cooler controller, the tact ...

Read More »

No.14 Rapid soldering cooling

《Problem Point 》 There was no good equipment to pinpoint the soldering to a low temperature. 《⇒Kaizen Point 》 An Air Blow Cooler was used. Pinpoint cooling is possible with the needle nozzle. Since the set temperature can be maintained ...

Read More »

No.13 Tensile tester low temperature setting

《Problem Point 》 There was no good equipment to pinpoint the sample to a low temperature. 《⇒Kaizen Point 》 An Air Blow Cooler was used. Pinpoint cooling is possible with the needle nozzle. Since the set temperature can be maintained ...

Read More »

No.12 Reproduction of thermal distortion

《Problem Point 》 There was no good equipment to pinpoint the sample to a low temperature. 《⇒Kaizen Point 》 An Air Blow Cooler was used. Pinpoint cooling is possible with the needle nozzle. Since the set temperature can be maintained ...

Read More »

No.11 Cooling and solidification of 3D printer

《Problem Point 》 There was no good equipment to pinpoint the modeling to a low temperature. 《⇒Kaizen Point 》 An Air Blow Cooler was used. Pinpoint cooling is possible with the needle nozzle. Since the set temperature can be maintained ...

Read More »

No.10 Electron microscope sample cooling

《Problem Point 》 There was no good equipment to pinpoint the sample to a low temperature. 《⇒Kaizen Point 》 An Air Blow Cooler was used. Pinpoint cooling is possible with the needle nozzle. Since the set temperature can be maintained ...

Read More »