Best Applications List

No.9 Refrigerant of Liebig condenser

《Problem Point 》 It was an environment where cooling water could not be used. 《⇒Kaizen Point 》 An Air Blow Cooler was used. With the combination of electricity and air, the water supply and drainage system could be omitted. Since ...

Read More »

No.8 Refrigerant of Dewar condenser

《Problem Point 》 It was an environment where cooling water could not be used. 《⇒Kaizen Point 》 An Air Blow Cooler was used. With the combination of electricity and air, the water supply and drainage system could be omitted. Since ...

Read More »

No.7 Refrigerant of Dimroth condenser

《Problem Point 》 It was an environment where cooling water could not be used. 《⇒Kaizen Point 》 An Air Blow Cooler was used. With the combination of electricity and air, the water supply and drainage system could be omitted. Since ...

Read More »

No.6 Refrigerant of Allihn condenser

《Problem Point 》 It was an environment where cooling water could not be used. 《⇒Kaizen Point 》 An Air Blow Cooler was used. With the combination of electricity and air, the water supply and drainage system could be omitted. Since ...

Read More »

No.5 Refrigerant of Graham condenser

《Problem Point 》 It was an environment where cooling water could not be used. 《⇒Kaizen Point 》 An Air Blow Cooler was used. With the combination of electricity and air, the water supply and drainage system could be omitted. Since ...

Read More »

No.4 Test tube cooling

《Problem Point 》 There was no good equipment to cool the test tube. 《⇒Kaizen Point 》 An Air Blow Cooler was used. Since the set temperature can be maintained with the Air Cooler Controller, the inspection accuracy has increased.

Read More »

No.3 Partial cooling of medium

《Problem Point 》 There was no good equipment to pinpoint the medium to a low temperature. 《⇒Kaizen Point 》 An Air Blow Cooler was used. Pinpoint cooling is possible with the needle nozzle. Since the set temperature can be maintained ...

Read More »

No.2 Low temperature drying of vials

《Problem Point 》 There was no good equipment for low temperature drying vials. 《⇒Kaizen Point 》 An Air Blow Cooler was used. Since the set temperature can be maintained with the cool air cooler controller, the tact time can be ...

Read More »

No.1 Vial cooling

《Problem Point 》 There was no good equipment to pinpoint the vials to a low temperature. 《⇒Kaizen Point 》 An Air Blow Cooler was used. Pinpoint cooling is possible with the needle nozzle. Since the set temperature can be maintained ...

Read More »

No.57 Surface modification of resin

[ Problem Point ] The hydrophilicity of the resin was not good. [ ⇒Kaizen Point ] Gas was brought into contact with the resin and irradiated with a halogen line heater. A synthetic thin film was formed on the surface, ...

Read More »

No.114 Simulation of smoke diffusion

[ Problem Point ] There was nothing that could heat the dummy gas at any temperature. [ ⇒Kaizen Point ] A air blow heater was used. Since there is a controller that can automatically control the temperature and hot air ...

Read More »

No.113 Activated carbon regeneration

[ Problem Point ] There was no device that was small and could be inlined. [ ⇒Kaizen Point ] Using hot air heater environment resistant type DGH series, Heated steam was blown into the activated carbon. The accumulated dirt was ...

Read More »

No.42 Synthesis of alloy particle

[ Problem Point ] There was no way to easily heat the metal particles to a high temperature. [ ⇒Kaizen Point ] It was heated to a high temperature using a halogen point heater. Stabilized heating at an arbitrary temperature ...

Read More »

No.40 Soldering of tip saw

[ Problem Point ] There was no easy way to set the tip of the tip saw to 1000℃ [ ⇒Kaizen Point ] It was heated to a high temperature using a halogen point heater. Since it can be processed ...

Read More »

No.3 Heating of glass plate

[ Problem Point ] There was ot a method to heat a part of the glass plate with far infrared rays. [ ⇒Kaizen Point ] Heated using a far infrared ray point heater FLH-35. The glass plate could be heated.

Read More »

No.1 Heating of test tube

[ Problem Point ] There was not a method to heat a part of test tube in far infrared rays. [ ⇒Kaizen Point ] Heated using a far infrared line heater FLH-30. Glass and a liquid were able to heat ...

Read More »

No.1 Pinpoint heating of resin

[ Problem Point ] There was no compact heater of far infrared which can pinpoint point the resin. [ ⇒Kaizen Point ] Heated using a far infrared ray point heater FPH-30. The welding of the resin got to work gently.

Read More »