Home / Halogen Point Heater / Basic knowledge of Halogen heater / 2.Halogen Point Heater / 2-6.Water-cooled and the temperature of the base

2-6.Water-cooled and the temperature of the base

Heat-resistant temperature of the base of the Halogen Point Heater is 180 ℃.

HPH30/35-24v-75w base part continuous temperature rise caused by current flow is about 200K.
If the room temperature and 30 ℃, the base temperature is raised to about 230 ℃.
This is a dangerous temperature exceeds 180 ℃ heat-resistant limit of this product.
Please keep the temperature under 180 ℃ of the base using the WCU-30 water-cooled unit.

In some cases, if not more than one minute continuous energization is not particularly heat dissipation measures are required.

Please check in a timely manner in the state of your body temperature.

HPH-60, please keep the temperature under 180 ℃ of the base using the WCU-60 water-cooled unit.

Water-cooling is basic for HPH120.
In some cases, it is 500w lamp and under 100 ℃, water cooling may not be necessary.

Water cooling is required in the case of more than one minute 1kw continuous lighting lamps.

HPH-160 is water-cooling essential.

D/# Heat-resistant Natural radiation Force-feed cooling
HPH-30 180℃ 75W 110W
HPH-35 180℃ 75W 110W
HPH-60 160℃ 150W 250W 300W 450W
HPH-120 500W 1kw
HPH-160 2kw 2.5kw 3kw

 Water-cooled and the temperature of the base  of the Halogen Point Heater1