[ Problem Point ] A low-cost, easy-to-use analytical method was needed. [ ⇒Kaizen Point ] It was used for pharmaceutical purity tests and follow-up confirmation tests for synthetic experiments. Fluoresces green under UV irradiation at 254 nm For detection by ...
Read More »No.17 Ultraviolet fluorescence method for quantification of uranium ore
[ Problem Point ] A small amount of uranium needed to be quantified. [ ⇒Kaizen Point ] A molten material made by adding a small amount of uranium to sodium fluoride emits a yellow-green fluorescent color when exposed to ultraviolet ...
Read More »No.16 Absorptiometry light source for total protein quantification method
[ Problem Point ] In order to collect samples after measurement, an analytical method that does not use additives was required. [ ⇒Kaizen Point ] Absorbance was measured at a UV wavelength of 280 nm to quantify protein. For a ...
Read More »No.15 Ultraviolet fluorescence method of sulfur dioxide
[ Problem Point ] It was necessary to measure the concentration of sulfur dioxide emitted into the atmosphere. [ ⇒Kaizen Point ] Fluorescence is emitted when the SO2 molecules excited by irradiating the sample with UVC return to the ground ...
Read More »No.14 Synthesis of vitamin D by UV irradiation
[ Problem Point ] Poor health due to lack of vitamin D. [ ⇒Kaizen Point ] Exposure to ultraviolet rays (UV-B) with a wavelength of around 300 nm for about 10 minutes a day, Vitamin D was synthesized in the ...
Read More »No.13 Glass lens ultraviolet (UV) cleaning
[ Problem Point ] For cleaning, it has been required a continuous reduction and dry process. [ ⇒Kaizen Point ] An ultraviolet lamp it was irradiated for a short time on the glass lens. By the action of active oxygen ...
Read More »No.12 UV surface modification of the resin printed board
[ Problem Point ] Printing of an ink-jet printer did not work out. [ ⇒Kaizen Point ] An ultraviolet lamp it was irradiated for a short time to the substrate. Improved wettability, ink-jet printing has become well.
Read More »No.11 Light herbicide
[ Problem Point ] It has been demanded a permanent herbicidal effect at a low cost. [ ⇒Kaizen Point ] An ultraviolet lamp it was irradiated for a short time to plant. We were conducting research to prevent the growth ...
Read More »No.10 Reading of the transparent UV ink
[ Problem Point ] For crisis management, we wanted to print the information on the product. [ ⇒Kaizen Point ] It was printed with UV ink. Since inconspicuous, it finished without changing the package design. Accuracy of crisis management has ...
Read More »No.9 Drying of UV printing
[ Problem Point ] To shorten the drying time of printing has been demanded. [ ⇒Kaizen Point ] Drying speed is fast, I was able to shorten the working time. The strength of the cover increases, and scrub scratch is ...
Read More »No.8 Weather resistance test of painting
[ Problem Point ] We wanted to accelerated test the weather resistance test in the laboratory. [ ⇒Kaizen Point ] It was irradiated with ultraviolet light in the body It is possible to adjust the wattage was take a multi-specific ...
Read More »No.7 Weather resistance test of the resin plate
[ Problem Point ] We wanted to accelerated test the weather resistance test in the laboratory. [ ⇒Kaizen Point ] It was irradiated with ultraviolet light in the resin plate It is possible to adjust the wattage was take a ...
Read More »No.6 The comparison test by the medium of Partial sterilization
[ Problem Point ] We wanted to a comparison test with a partial sterilization of the medium. [ ⇒Kaizen Point ] It was irradiated to the medium it with enclosure to ultraviolet light It is possible to adjust the wattage ...
Read More »No.5 Weather resistance acceleration test of color steel plate
[ Problem Point ] We wanted to accelerated test the light fastness test in the laboratory. [ ⇒Kaizen Point ] It was irradiated with ultraviolet light in color steel plate It is possible to adjust the wattage was take a ...
Read More »No.4 Permeability test of UV cut glass
[ Problem Point ] We have not been possible to find a small UV lamp. [ ⇒Kaizen Point ] It was irradiated with ultraviolet light to the UV cut glass It is possible to adjust the wattage was take a ...
Read More »No.3 Test of photocatalyst
[ Problem Point ] It could not by varying test the amount of the ultraviolet rays. [ ⇒Kaizen Point ] It was irradiated with ultraviolet light for the photocatalyst It is possible to adjust the wattage was take a multi-specific ...
Read More »No.2 Cracking test of tire
[ Problem Point ] Small ultraviolet lamp was necessary to carry out the cracking test of tire. [ ⇒Kaizen Point ] A precision part was heated hotly using a halogen point heater. It could be heated hotly by a pinpoint, ...
Read More »No.1 Irradiation to ultraviolet curable resin
[ Problem Point ] Shortening the resin hardening time has been required. [ ⇒Kaizen Point ] Curing speed is fast, it was able to shorten the working time. Since no cure and not irradiated with ultraviolet rays, constraints coating process ...
Read More »