Home / Best Applications List

Best Applications List

No.43 Heating of FPD

[ Problem Point ] We have no way to heated uniformly long area. [ ⇒Kaizen Point ] Heated by the Halogen Line Heater. Since the maximum temperature heated up in 5sec,immediately after the start of operation could work. Non-contact heating ...

Read More »

No.46 Dryness of the glass bottle

[ Problem Point ] It was dry by steam. When winter came,we were in trouble because it condensed into dew. [ ⇒Kaizen Point ] Heated and dried in the Air Blow Heater. The dewfall disappeared because it used dry air.

Read More »

No.42 Dryness and stiffening of wire covering

[ Problem Point ] We have no idea about high temperature heater on short time. [ ⇒Kaizen Point ] Heated by the Halogen Line Heater. Since the maximum temperature heated up in 5sec, immediately after the start of operation could ...

Read More »

No.45 Dryness of metal film

[ Problem Point ] The control of the surface tension of a metallic film was difficult when drying with the high temperature gas. [ ⇒Kaizen Point ] It dried using a wide nozzle by the Air Blow Heater. The surface ...

Read More »

No.44 Uniform heating of the medium

[ Problem Point ] It’ll be done only to heat a culture medium from the surface. It couldn’t be heated uniformly and in trouble. [ ⇒Kaizen Point ] The heating air was made with the Air Blow Heater. The accuracy ...

Read More »

No.40 Deposition of aluminum

[ Problem Point ] We have no idea how to deposition of aluminum in the vacuum chamber. [ ⇒Kaizen Point ] Heated by the Halogen Line Heater. Since the maximum temperature heated up in 5sec, immediately after the start of ...

Read More »

No.43 Heat sterilization of liquid by aeration

[ Problem Point ] It was troubled to be contaminated with airborne bacteria breeding in the liquid directly in the aeration air. [ ⇒Kaizen Point ] The aeration was done after heating was sterilized by the Air Blow Heater. Airborne ...

Read More »

No.39 Preliminary heating of metal material

[ Problem Point ] We have no way to the drawing press wrinkle. [ ⇒Kaizen Point ] Preheated metal material by the Halogen Line Heater. Since the maximum temperature heated up in 5sec, immediately after the start of operation could ...

Read More »

No.42 Drying of silicon wafers

[ Problem Point ] The conventional method was in trouble because it contains metal ions in dry air. [ ⇒Kaizen Point ] Heated and dried in the Air Blow Heater designed for clean room. Since heating the coated glass,and metal ...

Read More »

No.41 Dehumidification drying resin pellets

[ Problem Point ] We used the industry dryer. Unable to fine temperature control was a problem. [ ⇒Kaizen Point ] Heated and dried in large type the Air Blow Heater. Dehumidification and sufficient quality of injection molded raised in ...

Read More »

No.37 Adjustment of metal stiffening

[ Problem Point ] It is very difficult to annealing temperature control. [ ⇒Kaizen Point ] Heated by the Halogen Line Heater casting surface. Since the maximum temperature heated up in 5sec, immediately after the start of operation could work.The ...

Read More »

No.40 Heat shrinking of lithium batteries

[ Problem Point ] We used the industry dryer. Unable to fine temperature control was a problem. [ ⇒Kaizen Point ] Heated only the surface by the small calorie by the Air Blow Heater and made them shrink. Does not ...

Read More »

No.36 Heating in the vacuum chamber

[ Problem Point ] We have no idea about how to heat in the vacuum chamber. [ ⇒Kaizen Point ] Heated by the Halogen Line Heater. Since the maximum temperature heated up in 5sec, immediately after the start of operation ...

Read More »

No.39 Peel seal and Sticker remover

[ Problem Point ] Had trouble peeling off the seal is broken at the end. [ ⇒Kaizen Point ] A spot was heated by the Air Blow Heater and the glue was made soft. The productivity came off well,and improved.

Read More »

No.35 Keeping warm of food

[ Problem Point ] Rising of the heater is slow, the heat activity is bad. [ ⇒Kaizen Point ] Heated by the Halogen Line Heater. Since the maximum temperature heated up in 5sec, immediately after the start of operation could ...

Read More »

No.38 Ammonia gas heating

[ Problem Point ] The ammonia gas was dangerous,so it couldn’t be heated safely and I was in trouble. [ ⇒Kaizen Point ] It was heated airtightly by a DGH series of the Air Blow Heater. An experiment heated it ...

Read More »

No.34 Dryness of food

[ Problem Point ] Rising of the heater is slow, the productivity is bad. [ ⇒Kaizen Point ] Heated by the Halogen Line Heater. Since the maximum temperature heated up in 5sec, immediately after the start of operation could work.The ...

Read More »

No.33 Sterilization dryness of bottle ampoule

[ Problem Point ] Glass plate couldn’t interfere and heat the inner resin in a suitable temperature. [ ⇒Kaizen Point ] Passes through the glass , it was heated by the Halogen Line Heater. The product fineness has improved because ...

Read More »

No.36 Sterilization of spatula

[ Problem Point ] Until now had been roasted in the flames of gas pipe where the gas had no trouble using the impossible. [ ⇒Kaizen Point ] The Air Blow Heater to heat sterilization at high temperatures. If it ...

Read More »

No.32 Dryness of medicine pellet

[ Problem Point ] Glass plate couldn’t interfere and heat the inner resin in a suitable temperature. [ ⇒Kaizen Point ] Passes through the glass,it was heated by the Halogen Line Heater. The product fineness has improved because the temperature ...

Read More »

No.31 Dryness of triturate

[ Problem Point ] We have no idea about how to lead-free soldering of printed circuit boards. [ ⇒Kaizen Point ] Passes through the glass , it was heated by the Halogen Line Heater. The product fineness has improved because ...

Read More »