Air Blow Cooler controller ACC Series

[Attention]
ACC series can not control the Air Blow heater.
The control of the Air Blow Heater recommends HCA series, AHC3 series, and SSC series.
ACC series can not control the halogen heater.
The control of the halogen heater recommends HCV series, HHC2 series, and SSC series.

ACC performs stable cooling control by feedback control using a thermocouple.

[Specifications ]

D/# Features
ACC-0.7MPa-300L Temperature controller surface mounted
ACCP-0.7MPa-300L Temperature controller and pressure gauge surface mounted
ACCPFM-0.7MPa-200L Temperature controller, pressure gauge and flow meter surface mounted
ACCPFM-0.7MPa-300L Temperature controller, pressure gauge and flow meter surface mounted

Options

D/# Item and Description
TP  Thermo controller : Pyrometer input
TMR1  Mounting surface.-For one-shot cooling
TMR2  Mounting surface.-For thermal holding time
TMR3  Mounting surface.-cooling time for the predictive maintenance
RC1  Cooling start or stop in the signal from outside
RC2  Specified output voltage in 4-20mA from outside
RSP  Specified thermocontroller temp. in 4-20mA
MON  Monitor, Output 4-20mA signal the temperature of the cooling object.
RS485  RS-485 Communication
IOT  IOT function
TCB  Thermocouple break alarm
AP  Cooling air pressure shortage alarm
FPR  Front Protection Rail
RPR  Rear Protection Rail
PM  Pyrometer mounted surface.
FX570  Flexible Stand for Pyrometer
Pyrometer  Pyrometer to choice of applications, and then fitted adjusted to the heater controller.
Power Cable  Manufacture the specification of the power cable.
 +α  If user need a function other than the above, please contact us.

[Note] When the to add a function, there is that the external dimensions changes.

Standard type ACC

ACC has a separate main power switch and cooler start switch, so user can start cooling after setting the temperature.
And, it is possible to report that the cooling temperature has not been reached as an option.
In addition, the jetting temperature can be externally output to 4-20mA as an option.

Built-in pressure gauge ACCP

ACCP has a separate main power switch and cooler start switch, so user can start cooling after setting the temperature.
And, it is possible to report that the cooling temperature has not been reached as an option.
In addition, the jetting temperature can be externally output to 4-20mA as an option.

The ACCP is equipped with a pressure gauge so that user can visually check the pressure.
And, a pressure shortage alarm can be issued.
In addition, the pressure can be externally output to 4-20mA as an option.

Built-in pressure gauge and flowmeter ACCPFM

ACCPFM has a separate main power switch and cooler start switch, so user can start cooling after setting the temperature.
And, it is possible to report that the cooling temperature has not been reached as an option.
In addition, the jetting temperature can be externally output to 4-20mA as an option.

The ACCPFM is equipped with a pressure gauge so that user can visually check the pressure.
And, a pressure shortage alarm can be issued.
In addition, the pressure can be externally output to 4-20mA as an option.

The ACCPFM is equipped with a flow meter to visually check the flow rate.
And, a flow rate shortage alarm can be issued.
In addition, the flow rate can be externally output to 4-20mA as an option.

 

Catalog


PDF Catalog Download