INDEX
[Attention]
ACC series can not control the Air Blow heater.
The control of the Air Blow Heater recommends HCA series, AHC3 series, and SSC series.
ACC series can not control the halogen heater.
The control of the halogen heater recommends HCV series, HHC2 series, and SSC series.
ACC performs stable cooling control by feedback control using a thermocouple.
[Specifications ]
D/# | Features |
---|---|
ACC-0.7MPa-300L | Temperature controller surface mounted |
ACCP-0.7MPa-300L | Temperature controller and pressure gauge surface mounted |
ACCPFM-0.7MPa-200L | Temperature controller, pressure gauge and flow meter surface mounted |
ACCPFM-0.7MPa-300L | Temperature controller, pressure gauge and flow meter surface mounted |
Options
D/# | Item and Description |
---|---|
TP | Thermo controller : Pyrometer input |
TMR1 | Mounting surface.-For one-shot cooling |
TMR2 | Mounting surface.-For thermal holding time |
TMR3 | Mounting surface.-cooling time for the predictive maintenance |
RC1 | Cooling start or stop in the signal from outside |
RC2 | Specified output voltage in 4-20mA from outside |
RSP | Specified thermocontroller temp. in 4-20mA |
MON | Monitor, Output 4-20mA signal the temperature of the cooling object. |
RS485 | RS-485 Communication |
IOT | IOT function |
TCB | Thermocouple break alarm |
AP | Cooling air pressure shortage alarm |
FPR | Front Protection Rail |
RPR | Rear Protection Rail |
PM | Pyrometer mounted surface. |
FX570 | Flexible Stand for Pyrometer |
Pyrometer | Pyrometer to choice of applications, and then fitted adjusted to the heater controller. |
Power Cable | Manufacture the specification of the power cable. |
+α | If user need a function other than the above, please contact us. |
[Note] When the to add a function, there is that the external dimensions changes.
Standard type ACC
ACC has a separate main power switch and cooler start switch, so user can start cooling after setting the temperature.
And, it is possible to report that the cooling temperature has not been reached as an option.
In addition, the jetting temperature can be externally output to 4-20mA as an option.
Built-in pressure gauge ACCP
ACCP has a separate main power switch and cooler start switch, so user can start cooling after setting the temperature.
And, it is possible to report that the cooling temperature has not been reached as an option.
In addition, the jetting temperature can be externally output to 4-20mA as an option.
The ACCP is equipped with a pressure gauge so that user can visually check the pressure.
And, a pressure shortage alarm can be issued.
In addition, the pressure can be externally output to 4-20mA as an option.
Built-in pressure gauge and flowmeter ACCPFM
ACCPFM has a separate main power switch and cooler start switch, so user can start cooling after setting the temperature.
And, it is possible to report that the cooling temperature has not been reached as an option.
In addition, the jetting temperature can be externally output to 4-20mA as an option.
The ACCPFM is equipped with a pressure gauge so that user can visually check the pressure.
And, a pressure shortage alarm can be issued.
In addition, the pressure can be externally output to 4-20mA as an option.
The ACCPFM is equipped with a flow meter to visually check the flow rate.
And, a flow rate shortage alarm can be issued.
In addition, the flow rate can be externally output to 4-20mA as an option.