[ Problem Point ] We were looking for a heater that can heat high-pressure gas. [ ⇒Kaizen Point ] A halogen line heater is placed facing the metal pipe to heat it. Safe heating because it is in-line.
Read More »No.66 In-line heater for hydrogen gas heating
[ Problem Point ] We were looking for a heater that could safely heat hydrogen gas. [ ⇒Kaizen Point ] A halogen line heater is placed facing the metal pipe to heat it. Safe heating because it is in-line.
Read More »No.65 In-line heater for heating liquid ammonia
[ Problem Point ] We were looking for a heater that could safely heat liquid ammonia. [ ⇒Kaizen Point ] A halogen line heater is placed facing the metal pipe to heat it. Safe heating because it is in-line.
Read More »No.64 Inline heater for ammonia gas heating
[ Problem Point ] We were looking for a heater that could safely heat ammonia gas. [ ⇒Kaizen Point ] A halogen line heater is placed facing the metal pipe to heat it. Safe heating because it is in-line.
Read More »No.63 Evaluation of thermal responsiveness of thin ceramic plates
[ Problem Point ] We were looking for a heater to supplement the amount of heat dissipated from the thin plate. [ ⇒Kaizen Point ] Using a fast response halogen line heater. The accuracy of the feedback evaluation experiment has ...
Read More »No.62 Evaluation of metal heat storage material
[ Problem Point ] High speed heating was required to evaluate the responsiveness of the heat storage material. [ ⇒Kaizen Point ] Uses a halogen line heater that instantly heats up, The speed of the evaluation experiment has increased. I ...
Read More »No.61 Measures against freezing and frost formation in frozen warehouses
[ Problem Point ] Frequent malfunctions of heat shield doors due to freezing and sensors due to frost. [ ⇒Kaizen Point ] Because it vibrates and sublimates water molecules of frost and ice, It was possible to prevent frost and ...
Read More »No.60 Chemical liquid heater
[ Problem Point ] There was no good heater that could heat the chemical liquid at high speed. [ ⇒Kaizen Point ] Three halogen line heaters were combined to create a triangular space, and a quartz tube was passed through. ...
Read More »No.59 Lock-in infrared heat generation analysis-Lock-in thermography method
[ Problem Point ] We were looking for a heater that would synchronize with the pulse signal. [ ⇒Kaizen Point ] By changing the applied frequency, it was possible to limit the area of the heat generation point. When applied ...
Read More »No.58 Improved affinity for metal thin films
[ Problem Point ] The affinity of the metal thin film was not good. [ ⇒Kaizen Point ] The metal was heated and activated, and the affinity was improved.
Read More »No.57 Surface modification of resin
[ Problem Point ] The hydrophilicity of the resin was not good. [ ⇒Kaizen Point ] Gas was brought into contact with the resin and irradiated with a halogen line heater. A synthetic thin film was formed on the surface, ...
Read More »No.56 Heating of high temperature insulation material
[ Problem Point ] The creep characteristic of the high temperature heat insulating material could not be grasped. [ ⇒Kaizen Point ] And heated at high temperature using a halogen line heater. Since it can be heated to any temperature ...
Read More »No.55 Heating of microwave absorbing composite
[ Problem Point ] Microwave absorption characteristics of composite materials under high temperature environments could not be grasped. [ ⇒Kaizen Point ] Heated at high temperature using a halogen line heater. Since it can be heated to an arbitrary temperature ...
Read More »No.54 Borosilicate glass plate melting
[ Problem Point ] There was no substitute heat source to replace gas. [ ⇒Kaizen Point ] Borosilicate glass plate was melted using a halogen line heater. The glass tube processing process was composed only by electric equipment. In addition, ...
Read More »No.53 Heat test of the color filter
[ Problem Point ] It is necessary to shorten the new development time of a color filter. [ ⇒Kaizen Point ] We were using the parallel light type halogen line heater. Since the halogen heating type, it was able to ...
Read More »No.52 Sample heating in the vacuum chamber
[ Problem Point ] It is necessary to visually heating process. [ ⇒Kaizen Point ] We were using the parallel light type halogen line heater. Process is well understood since the heating change can be confirmed visually. We succeeded in ...
Read More »No.51 Heating and drying of the sealer
[ Problem Point ] It is necessary to shorten the drying time of the sealer. [ ⇒Kaizen Point ] We were using the line condensing type halogen line heater. Because the line condensing type, in accordance with the application position ...
Read More »No.50 Drying after car wash
[ Problem Point ] It is necessary to reduce the draining drying time. [ ⇒Kaizen Point ] We were using the parallel light type halogen line heater. Because the light heating, non-contact heating is possible, it was able to shorten ...
Read More »No.49 Heating and drying of hot melt
[ Problem Point ] It is necessary to shorten the drying time of the hot melt [ ⇒Kaizen Point ] We were using the line condensing type halogen line heater. Since the line condensing type, to suit the application position ...
Read More »No.48 Molecular alignment of the resin film sheet
[ Problem Point ] We wer looking for a linear heater capable of heating at high temperature required for the molecular alignment. [ ⇒Kaizen Point ] We use a condensing type heating equipment of halogen line heater.Molecular alignment of the ...
Read More »No.47 Preheating of Carbon Cloth
[ Problem Point ] We were looking for can be radiation uniformity, the heater of carbon fiber cloth, at high temperature for a short time. [ ⇒Kaizen Point ] We used combining the flat heating type of a halogen line ...
Read More »No.46 Drying and preheating of powder metal
[ Problem Point ] We were looking for can be radiation drying extensively, the heater of powder metals, at high temperatures. [ ⇒Kaizen Point ] We used surface heating type of the Halogen Line Heater.Because it is radiation heating, and ...
Read More »No.45 Heat source for instrument for analysis
[ Problem Point ] We are looking for not emit gases high temperature heater. [ ⇒Kaizen Point ] Heated by the Halogen Line Heater. It does not emit gases, it can accurate analysis. The idling time vanished, the current spending ...
Read More »No.44 Evaluation test on solar panel
[ Problem Point ] We have no way to powerful irradiated lamp with infrared and ultraviolet. [ ⇒Kaizen Point ] Irradiated infrared by the Halogen Line Heater. Also UV lamp, the same type of custom-made ones. Since the maximum temperature ...
Read More »No.43 Heating of FPD
[ Problem Point ] We have no way to heated uniformly long area. [ ⇒Kaizen Point ] Heated by the Halogen Line Heater. Since the maximum temperature heated up in 5sec,immediately after the start of operation could work. Non-contact heating ...
Read More »