Max.Temp.1400℃
Easily heating high temperatures!
◆ Feature ◆
- Easily heating high temperatures by the kit!
- Easily heating 1400℃ case by max.temperature.
- Easily adjusting the radiation diameter (focal size) by manual lift!
- Easily changing the heat power (wattage) by slide transformer!
- Easily cooling by cooling fan!
[ Power:5v/about17w ]
The output was adjusted to 5v by the slide transformer.
It can visually check the rated point in diameter Φ6 of 17w.
[ Power:36v/450w ]
It shine so very bright emission of heat generation 450W maximum output.
The diameter of a rated point cannot be visually checked.
[ Power:36v/450w Used the protective glass. ]
Then attached protective glasses are used,
positioning of an irradiation point can be performed easily visually.
Focal length and focus diameter of the Halogen Pont Heater HPH-60/f30
Example of lab kit assembly.
( ※The lab kit is delivered as individual components.)
【Lab kit packing product】
- Heater mounting bracket
- Manual lift.
Up and down 80 mm by 16 rotating knobs, the accuracy is 0.5 mm.
Manual lift. Platform surface is 100mm x 100mm, - Square Australia Brick. It is useful when place the test piece.
- Test stand Pole & Base
- Fan air cooling type Halogen Point Heater HPH-60FA/f30/36v-450w/GW
High power of 450w is condensed into Φ 6, heating the object. - Power cable for heater controller
- Manual variable power supply HCVD-AC100-240V/DC36V-600W
Input voltage in the range of AC100V-AC240V.
The output adjustable range DC0v ~ 36v.
Equipped with DC24V power for air cooling fan. - Safety glasses against high intensity light
It can visually check the high-intensity irradiation point at maximum output.