INDEX
1.Flow of model selection
- Determine the model in the installation environment.
- Determine the target temperature.
- Determine the required airflow.
- Obtain the power (Watt) from the table below ““Temperature and Airflow at the Maximum Power” ” table.
- Multiply the power by the safety factor twice to determine the number of model Watts.
- In the “Model List table” below, narrow down candidate models.
- Examine the external dimensions and details with the specification sheet of each model.
- Check the price in the price list.
- Order from the price list.
- In case user want to easy trial, we prepared 3 kinds of “Laboratory Kit”.
10-1.Air Blow Heater Laboratory Kit 4D-100W with air pump
10-2.Air Blow Heater Laboratory Kit 13NM-220V-350W external air supply
10-3.Air Blow Heater Laboratory Kit 34NM-220V-3kW(External air supply Type)
2.Model selection in installation environment
Q1.Is it installed in a vacuum chamber? Yes ⇒ VAH type
Q2.Is it installed in a clean room? Yes ⇒ DGH type
Q3.Is the heated gas corrosive gas? Yes ⇒ DGH type
If it does not apply to the above Q1 to Q3, select standard ABH type
3.“Temperature and Air flow at the Maximum Power” graph
4.Model List
5.Selection example
【Example】 I want a hot air at 500 ℃ with air flow of 40ℓ/min, installed at factory.
5-1.Since normal air is used in an environment of normal temperature and normal pressure, standard ABH type is selected
5-2.”Temperature and Air flow at the Maximum Power 100W – 550W” Check the graph.
5-2-1.A point of intersection of 40 (ℓ/mint) and 500 ℃ is asked.
5-2-2.A point of intersection will be a line of 440W.
5-2-3.Calculate 880 W by multiplying 440 W by the safety factor of 200% due to disturbance.
5-2-4.The rating near 880 W is 1 kW.
5-3.Confirm the “Model List of Air Blow Heaters” table.
[ Applicable model ] ABH-15 S 650 – 1.6kW
5-4.Details confirmed on “ABH – 15 S” site.
In this case ABH-230V-1kW/15PS/+S/+PS2 m selected