[ Problem Point ] A low-cost, easy-to-use analytical method was needed. [ ⇒Kaizen Point ] It was used for pharmaceutical purity tests and follow-up confirmation tests for synthetic experiments. Fluoresces green under UV irradiation at 254 nm For detection by ...
Read More »No.17 Ultraviolet fluorescence method for quantification of uranium ore
[ Problem Point ] A small amount of uranium needed to be quantified. [ ⇒Kaizen Point ] A molten material made by adding a small amount of uranium to sodium fluoride emits a yellow-green fluorescent color when exposed to ultraviolet ...
Read More »No.16 Absorptiometry light source for total protein quantification method
[ Problem Point ] In order to collect samples after measurement, an analytical method that does not use additives was required. [ ⇒Kaizen Point ] Absorbance was measured at a UV wavelength of 280 nm to quantify protein. For a ...
Read More »No.15 Ultraviolet fluorescence method of sulfur dioxide
[ Problem Point ] It was necessary to measure the concentration of sulfur dioxide emitted into the atmosphere. [ ⇒Kaizen Point ] Fluorescence is emitted when the SO2 molecules excited by irradiating the sample with UVC return to the ground ...
Read More »For cold cathode low pressure mercury lamps For Ultraviolet rays point type irradiator UVP-60 Manual power supply controller UVPC-1500V
Color universal design UVPC-1500V series A blue indicator light has been adopted to make it easy for anyone to see. It has a built-in inverter and can light UVP-60 and cold cathode type ultraviolet lamps. Note – Cannot be used ...
Read More »For Ultraviolet rays point type irradiator UVP-30 Manual power supply controller UVPC3.6V
Color universal design UVCP3.6V series A blue indicator light has been adopted to make it easy for anyone to see. A dial is included to allow manual current control of the UVP-30 at 3.6V. Note – Cannot be used for ...
Read More »Ultraviolet point type irradiation device Laboratory-kit LKUVP-60 + UVPC
Focal sizeΦ12 Sterilization UV spot irradiation can be done easily! ◆ Feature ◆ Since it is a kit, user can easily use the UV irradiation device. UV irradiation of 375 nm is possible. UV irradiation of Φ13 can be easily reproduced. The ...
Read More »Ultraviolet point type irradiation device Laboratory-kit LKUVP-30 + UVPC
Focal sizeΦ13 Easily UV point irradiation! ◆ Feature ◆ Since it is a kit, user can easily use the UV irradiation device. UV irradiation of 375 nm is possible. UV irradiation of Φ13 can be easily reproduced. The manual variable power supply ...
Read More »UV Ray line type Irradiator Lab Kit LKUVL-115
Easy UV irradiation! ◆ Features◆ 1). Since it is a kit, user can easily irradiate UV rays. 2). Built-in amplifier makes lighting operation easy. 3). Irradiate 253.7 nm, which has a high sterilization effect, with a large output of 8 ...
Read More »UV point type irradiator UVP-60 series
1.Features of UVP-60 1) UV-C 253.7nm irradiation is possible. 2) UVP-60 is compact and can irradiate a point of φ12 with UV rays. UVP-60 is an ultraviolet point type irradiator that points the light of an ultraviolet lamp with a ...
Read More »Compact UV point type irradiator UVP-30 series
1. Features of UVP-30 1) UVP-30 is compact and can irradiate a point of φ13 with UV rays. UVP-30 is an ultraviolet point type irradiator that points the light of an ultraviolet lamp with a condensing mirror. 2) User can ...
Read More »No.14 Synthesis of vitamin D by UV irradiation
[ Problem Point ] Poor health due to lack of vitamin D. [ ⇒Kaizen Point ] Exposure to ultraviolet rays (UV-B) with a wavelength of around 300 nm for about 10 minutes a day, Vitamin D was synthesized in the ...
Read More »No.13 Glass lens ultraviolet (UV) cleaning
[ Problem Point ] For cleaning, it has been required a continuous reduction and dry process. [ ⇒Kaizen Point ] An ultraviolet lamp it was irradiated for a short time on the glass lens. By the action of active oxygen ...
Read More »No.12 UV surface modification of the resin printed board
[ Problem Point ] Printing of an ink-jet printer did not work out. [ ⇒Kaizen Point ] An ultraviolet lamp it was irradiated for a short time to the substrate. Improved wettability, ink-jet printing has become well.
Read More »No.11 Light herbicide
[ Problem Point ] It has been demanded a permanent herbicidal effect at a low cost. [ ⇒Kaizen Point ] An ultraviolet lamp it was irradiated for a short time to plant. We were conducting research to prevent the growth ...
Read More »No.10 Reading of the transparent UV ink
[ Problem Point ] For crisis management, we wanted to print the information on the product. [ ⇒Kaizen Point ] It was printed with UV ink. Since inconspicuous, it finished without changing the package design. Accuracy of crisis management has ...
Read More »No.9 Drying of UV printing
[ Problem Point ] To shorten the drying time of printing has been demanded. [ ⇒Kaizen Point ] Drying speed is fast, I was able to shorten the working time. The strength of the cover increases, and scrub scratch is ...
Read More »No.8 Weather resistance test of painting
[ Problem Point ] We wanted to accelerated test the weather resistance test in the laboratory. [ ⇒Kaizen Point ] It was irradiated with ultraviolet light in the body It is possible to adjust the wattage was take a multi-specific ...
Read More »No.7 Weather resistance test of the resin plate
[ Problem Point ] We wanted to accelerated test the weather resistance test in the laboratory. [ ⇒Kaizen Point ] It was irradiated with ultraviolet light in the resin plate It is possible to adjust the wattage was take a ...
Read More »No.6 The comparison test by the medium of Partial sterilization
[ Problem Point ] We wanted to a comparison test with a partial sterilization of the medium. [ ⇒Kaizen Point ] It was irradiated to the medium it with enclosure to ultraviolet light It is possible to adjust the wattage ...
Read More »No.5 Weather resistance acceleration test of color steel plate
[ Problem Point ] We wanted to accelerated test the light fastness test in the laboratory. [ ⇒Kaizen Point ] It was irradiated with ultraviolet light in color steel plate It is possible to adjust the wattage was take a ...
Read More »No.4 Permeability test of UV cut glass
[ Problem Point ] We have not been possible to find a small UV lamp. [ ⇒Kaizen Point ] It was irradiated with ultraviolet light to the UV cut glass It is possible to adjust the wattage was take a ...
Read More »No.3 Test of photocatalyst
[ Problem Point ] It could not by varying test the amount of the ultraviolet rays. [ ⇒Kaizen Point ] It was irradiated with ultraviolet light for the photocatalyst It is possible to adjust the wattage was take a multi-specific ...
Read More »No.2 Cracking test of tire
[ Problem Point ] Small ultraviolet lamp was necessary to carry out the cracking test of tire. [ ⇒Kaizen Point ] A precision part was heated hotly using a halogen point heater. It could be heated hotly by a pinpoint, ...
Read More »UV equipment Product List
UV Irradiator Lab Kit UVP-30-LK UV Irradiator Lab Kit UVP-60-LK UV Irradiator Lab Kit UVL-115-LK Ultraviolet point type irradiation device UVP-30 Ultraviolet point type irradiation device UVP-60 Ultraviolet line type irradiation device UVL-115 ...
Read More »